Skip to content

0015 — Optically anisotropic materials (substrates, layers, structured parts)

Status: accepted Date: 2026-11-01 (proposed and accepted after review the same day)

Context

Semiconductor metrology and device optics need optically anisotropic media in substrates, in unstructured layers and in structured parts: sapphire, SiC, GaN, LiNbO₃/LiTaO₃, TiO₂ (uniaxial), biaxial films, crystals cut off-axis (the optic axis rotated against the interface and against the grating lines), and, as a weak effect, strained silicon. Cross-polarised reflection (r_sp, r_ps) and Mueller-matrix scatterometry are the quantities of interest.

Facts from the code (main after M17 S3):

  • The assembly is tensor-ready: assembly::MaxwellForm<Dim> carries complex tensors ε(x) and μ⁻¹(x); the PML is already implemented as an anisotropic material (ADR-0005, validated by tests/convergence/pml_reflection.cpp); ConicalForm and the axisymmetric forms carry diagonal tensors only.
  • materials::Material is isotropic: the public fields eps_r, mu_r (include/hpfem/materials/material.hpp, which names anisotropy as "later"). Scattering::form_of_cell builds ε_r·I, μ_r⁻¹·I. eps_r appears in 51 files of src/, include/, python/ (203 hits), mu_r in 37.
  • physics::LayerStack (ADR-0009) assumes isotropic layers (scalar k_z per layer, s/p polarisations); docs/axisymmetric-layered-features.md lists anisotropic layers as out of scope. diffraction, farfield, waveguide_port, propagating_mode, mie, absorption and the dipole scan (ADR-0013) use scalar indices.
  • The direct solvers choose their path by detect_symmetry (ADR-0008): complex-symmetric systems take the LDLᵀ paths, the others the general LU.
  • Several conical paths rely on the symmetry of the unreduced matrix A(β): the adjoint of the goal-oriented estimator is assembled from A instead of Aᵀ (src/physics/conical_goal.cpp), and the emission pattern of M17 S2 (grating.emission_pattern, ADR-0013 §6) is computed by reciprocity at the same β.
  • hpfem.materials (Dispersive: Constant, Tabulated, Sellmeier, DrudeLorentz) returns scalars.

Decision

1. Material model

materials::Material gains an optional tensor part (std::shared_ptr<const Tensors> with a complex 3×3 eps), so that isotropic materials keep their size and speed. is_isotropic(), eps_tensor() (returns eps_r·I for isotropic) and mu_inv_tensor() are the tensor-aware accessors. Scalar access to an anisotropic material throws (eps_scalar(), used by every path not yet migrated): an unsupported feature fails loudly instead of computing with a wrong scalar. Every such path also reports a hpfem.diagnostics entry anisotropic_unsupported with the feature name before it fails.

A public data member cannot throw, so eps_r and mu_r become private with the accessors eps_scalar() / mu_scalar() and the constructors Material::isotropic(eps, mu = 1) and Material::anisotropic(eps_tensor). This is a breaking change of the C++ API (reads and writes of Material::eps_r / mu_r). Transition: S1 replaces all uses inside the repository in one change; the two-argument constructor Material(eps_r, mu_r) keeps Material{eps, mu} compiling.

Amendment (S1, 2026-11-01): the Python API does not break. A Python property can raise, so Material.eps_r stays as the scalar property (it raises hpfem.AnisotropicUnsupported for a tensor material, and setting it makes the material isotropic) instead of becoming a deprecated alias. The diagnostic code is anisotropic_unsupported, in the snake_case of the existing codes. The diagnostic is reported by the Python entry points that run diagnostics (grating.validate / solve, validate_scattering); C++ paths and other Python paths fail with the exception. The isotropic-limit regression (§9 item 1) moves to S2, the first stage with a tensor path to compare.

μ stays scalar. Optical crystals have μ = 1; the assembly keeps full μ⁻¹ tensors for the PML, but Material carries no μ tensor. This keeps the 4×4 system of §5 in its simple form and halves the test matrix; a μ tensor (metamaterial homogenisations) needs an amendment of this ADR.

The tensors are given in the laboratory frame (x, y along the lattice, z the layer normal of the 3D and stack solvers; the conical solver's own frame in §4); the crystal frame and its rotation are a Python concern (§6).

2. Volume solvers (Scattering 2D/3D)

form_of_cell returns tensors; with a layered background the source is k0² (ε_c(x) − ε_stack(z_c)) E_inc as a matrix product, so it still vanishes where the structure equals the stack, in particular inside the PML. The PML stretches by ε̃_ij = ε_ij · s_x s_y s_z / (s_i s_j) (and μ̃ likewise). Residual and goal-oriented estimators use ε in the divergence term and the n·εE jump. Per-cell overrides (MaterialMap::set_cell) accept anisotropic materials, which also gives position-dependent tensors (strain, graded axes) and a path for ThermoOptical.

PML stability. The coordinate-stretching PML absorbs a wave only if the component of its group velocity along the stretching direction has the same sign as the component of its phase velocity, the geometric condition of Bécache, Fauqueux & Joly (2003). This fails not only in hyperbolic media but already in an ordinary uniaxial or biaxial crystal whose axis is tilted against the PML normal: an extraordinary wave can carry power into the PML with its phase travelling out of it, and the stretch then amplifies it. Consequences:

  • form_of_cell computes, per PML layer, the slowness curve of the medium along the stretching direction for the in-plane wave vectors of interest and reports a diagnostic pml-backward-wave with the medium and the direction where the condition fails; axes aligned with the PML normal or lying in the PML plane never trigger it.
  • For periodic structures over a tilted anisotropic substrate the substrate side is truncated by a modal transparent boundary (Dirichlet-to-Neumann map of the 4×4 eigenmodes of the half-space for every Fourier order, from §5) instead of a PML; this also gives the mode-resolved orders of §7 directly. For isolated structures in such a substrate the first step stops with the diagnostic.

Amendment (S2, 2026-11-05): the statement above that aligned axes never trigger the diagnostic holds for uniaxial crystals (optic axis along the normal or in the layer plane) only. An aligned biaxial crystal violates the geometric condition along its intermediate principal axis: near the optic axes the group velocity of one sheet sweeps the cone of internal conical refraction, which reaches across the layer plane (min k_d v_d ≈ −0.01 for ε = diag(2, 3, 4.5), checked independently with the gradient of ω(k)). The diagnostic therefore also fires there; it is a warning, since only waves near the optic axes are affected. The check samples the wave directions (pml::backward_wave, docs/theory/materials.md). In the 2D solver the tensor is the in-plane block; a tensor coupling the plane to z is refused there (anisotropic_unsupported), not approximated.

3. Solver symmetry

A material with ε = εᵀ (all non-gyrotropic crystals, also rotated by a real rotation and absorbing) keeps the 3D and the 2D in-plane curl–curl system complex-symmetric; detect_symmetry routes such systems to LDLᵀ (MUMPS, cuDSS). This does not hold for the conical solver once the tensor couples the longitudinal to the in-plane components (§4). Gyrotropic and optically active media (antisymmetric parts ε_ij = −ε_ji) are out of scope of the first step: they break reciprocity, on which the far field and the emission pattern by reciprocity rely; they would use the general LU through the same detection.

4. Conical (grating) solver

ConicalForm goes from diagonal to full 3×3 tensors (ε full, μ⁻¹ full for the PML only). The derivation is short and goes into the conical section of docs/theory/maxwell.md:

  • Interface conditions need no re-derivation. They are natural in the weak form: the continuity of the tangential field (the in-plane tangential component and E_z, since z is tangential to every interface of a z-invariant structure) is built into the Nédélec × H1 pair, and the continuity of n·(εE) with n in the (x, y) plane and of the tangential H is natural. The gradient kernel conical_gradient does not depend on the material and stays exact.
  • The scaled components break the symmetry. With E = (E_t, iv) e^{iβz}, test functions V = (V_t, −iw) e^{−iβz} and the curls curl E = D c_E, curl V = D̄ c_V, D = diag(i, −i, 1) (c the real-structured curl components of the conical section), the cell matrices are c_Vᵀ (D̄ μ⁻¹ D) c_E and V̂ᵀ (D'' ε D') Ê with D' = diag(1, 1, i), D'' = diag(1, 1, −i). Their entries are, for a symmetric tensor:
coupling stiffness factor mass factor symmetric
xx, yy, zz 1 1 yes
xy −1 (both entries) 1 yes
xz, yz ∓i (antisymmetric pair) ±i (antisymmetric pair) no

So A(β) is complex-symmetric only if ε_xz = ε_yz = 0 (and μ⁻¹_xz = μ⁻¹_yz = 0, which the diagonal PML stretch keeps). In general A(β)ᵀ = S A(−β) S with S = diag(I, −I) (sign of the scaled E_z block): reciprocity pairs β with −β. Physically, an optic axis with a component along the grating lines that is not perpendicular to them breaks the mirror symmetry z → −z. - Consequences in the code. kDetect already routes the non-symmetric matrices to the general LU. Every path that uses symmetry must use the transposed system instead: the adjoint of conical_goal (assemble Aᵀ, i.e. S A(−β) S, not A), the emission pattern by reciprocity (ADR-0013 §6: the reciprocal problem at −β), the power matrix on a kept factorisation (ConicalSweep, transposed solves of the same factorisation) and the material and shape sensitivities (ADR-0011). Each gets a unit test with a tilted axis that compares the transposed path to a forward solve. - The scalar E_z path breaks. At β = 0 the terms ε_xz, ε_yz couple E_z to the in-plane field, so the E_z / H_z polarisations no longer decouple; ConicalScatteringSetup::scalar_ez rejects such materials with a diagnostic. - Staging. S3 first takes tensors with ε_xz = ε_yz = 0 (optic axis in the cross-section plane or along the lines: symmetric, no change of the symmetry-based paths), then the general tensor with the transposed paths.

The conical estimators follow §2. Checked against the 3D solver (§9, item 5).

Amendment (S3, 2026-11-05): frame of the grating module. hpfem.materials and every Python entry point take tensors in the laboratory frame of §1 (x across the lines, y along them, z the layer normal). The conical solver computes in its own frame (x across the lines, y the layer normal, z along the lines); hpfem.grating maps a crystal given in a dict by ε_conical = P ε_lab Pᵀ with P swapping y and z, so that the azimuth φ runs from x towards the lines in both frames (P is a reflection; harmless for a symmetric tensor). A MaterialMap with crystals is refused by hpfem.grating (its frame would be ambiguous); the C++ ConicalScatteringSetup takes the conical frame. Staging: both stages of §4 came at once (diagonal tensors keep their assembly, full tensors take the general product). The transposed paths found two latent errors that only crystals with ε_xz, ε_yz expose: the assembling conical_adjoint_solution and conical_dwr_estimate solved with A instead of Aᵀ, and conical_resonance_adjoint took y = x without constraints; both are fixed and checked against finite differences. The reciprocity paths of hpfem.grating (emission pattern, array scan) still refuse crystals: their mirrored cell for the substrate directions would need the mirrored tensor.

5. Anisotropic layer stack

LayerStack layers and the substrate may carry anisotropic materials; the incidence medium stays isotropic and lossless (as today). Per layer the in-plane wave vector (k_x, k_y) fixes a 4×4 system for the tangential fields (Berreman 1972, Yeh 1979), ∂_z ψ = i K ψ, ψ = (E_x, E_y, H_x, H_y), obtained by eliminating E_z and H_z; this requires ε_zz ≠ 0, and an epsilon-near-zero ε_zz is rejected with a diagnostic.

Degenerate and defective cases. The eigenvectors of K are not a reliable basis: every isotropic layer is doubly degenerate (the common case in a mixed stack), a uniaxial axis near z or near-normal incidence makes the individual eigenvectors ill-conditioned, and absorbing biaxial media have exceptional points (Voigt waves) where K is defective. The stack therefore never diagonalises K. It computes the ordered complex Schur form K = U T Uᴴ with the two upward eigenvalues first; the leading two columns of U span the upward invariant subspace, which is well-conditioned under degeneracy and defined at a defective point. Propagation through a layer uses the 2×2 matrix exponentials of the diagonal blocks of T, and the stable S-matrix recursion from the substrate upwards works with these subspaces only (layer-local amplitudes, decaying exponentials only, as in ADR-0009 §2) — no transfer-matrix products through thick or absorbing layers. Up / down is decided by Im k_z > 0 for evanescent and absorbing modes and by the sign of the Poynting flux S_z for propagating lossless modes; grazing modes (k_z = 0, Rayleigh anomalies) are handled as in the isotropic stack. Isotropic layers keep the closed s/p forms as the fast path and as the test reference.

Individual modes are needed only in the substrate and the incidence medium, for the output: in a uniaxial substrate the ordinary mode is defined through the optic axis (D ⊥ axis), the extraordinary one as the other mode of the subspace; in a biaxial substrate the two modes are the eigenvectors of the upward 2×2 block, made unique at a degeneracy by power orthogonality. Outputs: the Jones matrix (r_ss, r_sp, r_ps, r_pp and the transmission channels into the substrate modes), the mode amplitudes and the analytic field (value and curl) per layer for the scattered-field source.

6. Python layer and data

hpfem.materials.Anisotropic combines three principal Dispersive models with an orientation, .at(omega) returns the tensor Material. The tensor is R diag(ε_1, ε_2, ε_3) Rᵀ with real R, hence symmetric (§3). Orientation conventions, fixed here:

  • Uniaxial (Uniaxial(n_o, n_e, theta, phi)): the optic axis by its polar angle θ from the laboratory z axis and its azimuth φ from the x axis towards y, as used in metrology (c-plane: θ = 0; a- and m-plane: θ = 90°).
  • Biaxial: intrinsic z-x-z Euler angles (α, β, γ), R = R_z(α) R_x(β) R_z(γ), mapping the principal (crystal) frame to the laboratory frame; documented with a figure in a new page docs/theory/materials.md (written in S1).

The refractiveindex.info loader reads the separate ordinary / extraordinary entries of uniaxial materials where the database has them.

Amendment (S5b, 2026-11-05): in a periodic problem only the discrete in-plane wave vectors of the orders reach the PML, so the instability needs an outgoing propagating order that is a backward wave. In a tilted uniaxial crystal this happens in a narrow window of the tangential wavenumber just inside the cutoff of the extraordinary sheet (for ε_o = 2.4, ε_e = 3.4, axis 0.7 rad from the normal: a ≈ −1.71…−1.68), i.e. for diffracted orders, not for the zeroth order of incidence from air. There the PML stalls at a fixed error (the energy balance of a lossless grating at 10⁻⁴ for every p) and the modal boundary converges (anisotropic_modal_boundary). The modal boundary is implemented for the conical solver as a per-order Dirichlet-to-Neumann term (ConicalScatteringSetup::modal_boundaries, docs/theory/anisotropic-stack.md); the 3D solver keeps the diagnostic.

7. Post-processing

  • Diffraction orders in an anisotropic half-space are decomposed on the two modes of that half-space (§5, tangential E_t, H_t), not on s/p; every order has an ordinary and an extraordinary (or two biaxial) channels with their own k_z and power. In isotropic half-spaces the existing s/p decomposition stays.
  • Absorption uses Q = ω/2 · Eᴴ (ε − εᴴ)/(2i) E; the Poynting flux uses H = (iωμ)⁻¹ curl E (μ scalar, §1).
  • Far field and cross-sections only in isotropic cover media (the reciprocity far field needs the Green's function of the half-space); anisotropic substrates are measured through the mode-resolved orders and fluxes.
  • New output: Jones and Mueller matrix of each order and of the specular channel. The s/p basis of the incoming and outgoing waves follows the convention of conical_polarisation(k, n̂, s|p) (s = k̂ × n̂ normalised, p = s × k̂ for both waves), stated in docs/theory/maxwell.md together with the reciprocity relations of §9.

8. Axisymmetric solver and emitters

The axisymmetric solver takes diagonal tensors in (r, φ, z) (c-axis along z, or radial / azimuthal axes); an optic axis tilted against z breaks the rotational symmetry and is rejected with a diagnostic. The dipole scan (ADR-0013) needs the Green's function of the anisotropic stack (Sommerfeld integral with the 4×4 formalism of §5, poles and branch cuts of the extraordinary and ordinary modes) and the β ↔ −β reciprocity of §4; it is a separate later stage with its own ADR amendment once §5 and §7 are validated.

Amendment (S7, 2026-11-05): emitters above crystal stacks. The emitter stays the Gaussian dipole of ADR-0013 in an isotropic, lossless host (the cover or an isotropic layer); hosts that are crystals need their own bulk power and are not part of S7. Decisions, in stages:

  • S7a, reference. The power of a point dipole above an AnisotropicStack is computed from the 2D plane-wave (Weyl) spectrum of the Green's dyadic and the Jones reflection of the stack at every in-plane wavevector, propagating and evanescent (AnisotropicStack::reflection_at, hpfem.planar.dipole_above_stack), not from a 1D Sommerfeld integral: without rotational symmetry the azimuth of the in-plane wavevector does not separate. The radial integral runs on the real axis; guided modes of lossless stacks (real-axis poles) are excluded, the references use absorbing layers or stacks without guided modes. Complex in-plane wavevectors (a deformed path through the 4×4 system) are deferred. The Gaussian smearing multiplies every spectral component by exp(−σ² k·k) = exp(−(n k0 σ)²) and cancels in the Purcell factor, so the point dipole is the exact reference of the FEM emitter.
  • S7b, one sample. grating.emit with an AnisotropicStack: one Bloch sample (kx, β) of a flat stack is the plane-wave spectrum on the orders (kx + 2πm/P, β), which gives an exact reference for the delivered power of the cell problem.
  • S7c, array scan. For crystals the (kx, β) integrand is in general neither even in β nor in kx: dipole_emission integrates β over (−∞, ∞) and kx over the full zone, keeps every entry of the power matrix (no zeroing of odd entries), and takes the light lines and branch points of crystal media from their ordinary / extraordinary roots (half_space_modes). The reciprocity of a symmetric tensor, A(kx, β)ᵀ = S A(−kx, −β) S, pairs the samples at (kx, β) and (−kx, −β) and may halve the work later; S7c does not rely on it.
  • S7d, channels by reciprocity. The substrate directions of the reciprocity path mirror the cell; a crystal needs the mirrored tensor M ε M (M = diag(1, −1, 1) in the solver frame) or a plane wave incident from the substrate (M19 S3c).

9. Validation (each stage with an independent reference)

  1. Isotropic limit: a tensor ε·I must reproduce every existing benchmark and test to round-off (guards the migration).
  2. Homogeneous plate: uniaxial with the optic axis in the plane, along the normal and tilted; reference an independent 4×4 transfer-matrix implementation in the tests (NumPy, eigenvector-based, thin layers only) plus the closed forms (normal incidence with the axis in the plane: two Fabry–Pérot problems with n_o and n_e).
  3. Degenerate cases of the stack: isotropic layers between anisotropic ones, axis exactly along z at normal incidence, axis 10⁻⁶ rad off z (results continuous in the angle), and an absorbing biaxial layer at a Voigt direction (results continuous across it).
  4. Energy balance: R + T + A = 1, lossless and absorbing, all four Jones channels.
  5. Form birefringence: a sub-wavelength grating of isotropic materials against the homogeneous uniaxial plate of effective-medium theory (structured against unstructured), then the same with an anisotropic grating material; published Fourier-modal results for anisotropic gratings (L. Li 2003) where they cover the case.
  6. Cross-consistency and symmetry: the grating and the crystal rotated by the same azimuth, conical against the 3D solver. Symmetry checks on a plate with the axis in the plane at the azimuth α against the plane of incidence: r_sp(−α) = −r_sp(α) and r_ps(−α) = −r_ps(α) with r_ss, r_pp even in α (mirror at the plane of incidence); r_sp = r_ps = 0 for the axis in or perpendicular to the plane of incidence.
  7. PML: pml_reflection extended to media with a full tensor, axis aligned (no diagnostic, reflection as today) and tilted (the diagnostic pml-backward-wave fires where the geometric condition fails; the modal boundary of §2 reproduces the stack reference there).
  8. Reciprocity: for a reciprocal (non-gyrotropic) structure the Jones matrix of the reversed path satisfies r_ps(k_in → k_out) = −r_sp(−k_out → −k_in) and r_ss, r_pp equal, with the sign fixed by the s/p convention of §7; checked on a rotated crystal in the stack and in the conical solver (which exercises the β ↔ −β pairing of §4).
  9. Conical symmetry: the assembled conical matrix is complex-symmetric for ε_xz = ε_yz = 0 and satisfies A(β)ᵀ = S A(−β) S for a general symmetric tensor (unit test on the cell matrices).

Consequences

  • Safe migration: because scalar access throws, each of the ~50 files is either migrated or refuses anisotropic input with a diagnostic; there is no silent wrong answer. The price is a breaking change of the C++ Material (private fields), absorbed in one change; the Python API keeps eps_r as a property. The migration order (stages in the roadmap, M19) follows the use: volume solvers and the stack first, then the conical solver, then the rest.
  • No cost for isotropic runs: isotropic materials stay scalar; the tensor path is taken only when a cell carries a tensor. The solver symmetry is kept for non-gyrotropic crystals in the 3D and 2D solvers and for the conical solver with ε_xz = ε_yz = 0.
  • Conical symmetry loss: a general tilted crystal in the conical solver costs the general LU (roughly twice the factorisation memory of LDLᵀ) and requires the transposed paths of §4 in the adjoint, reciprocity and sensitivity code.
  • Larger numerical work: the Schur-based stack (§5), the transposed conical paths (§4) and the modal substrate boundary (§2) are the risks; each is checked against an independent reference before the dependent stages start.
  • Limits stay visible: gyrotropy, a μ tensor, ε_zz → 0 in the stack, tilted axes in the axisymmetric solver, anisotropic cover media, isolated structures in a tilted substrate (PML condition) and the anisotropic emitter scan are out of scope and fail with diagnostics.

Alternatives considered

  • Always-tensor Material (3×3 for every material): simplest to reason about, but touches every one of the 203 eps_r uses at once, costs memory and time for the dominant isotropic case and makes the migration an all-or-nothing change.
  • Keeping eps_r public and documenting that it is meaningless for anisotropic materials: no API break, but exactly the silent wrong answer the throwing accessor prevents.
  • Only diagonal anisotropy: covers on-axis uniaxial crystals, but not the rotated crystals (c-plane / a-plane / r-plane cuts at an angle to the grating) that metrology needs, and gives no cross-polarisation.
  • Effective isotropic media for form birefringence only: correct for deep sub-wavelength structures, wrong for real crystals and for structures near the diffraction limit.
  • Transfer-matrix (4×4) instead of the S-matrix recursion: short, but loses digits in thick or absorbing layers, which ADR-0009 already rejected for the isotropic stack.
  • Eigenvector basis per layer (closed forms for uniaxial layers, a projection for degenerate pairs): the textbook route, but ill-conditioned near degeneracies and undefined at the exceptional points of absorbing biaxial media; the ordered Schur form covers all cases with one code path.
  • A different conical scaling (e.g. V_z = iw) to restore symmetry: it changes only the sign of the zz block and moves the antisymmetry elsewhere; the loss of symmetry is physical (z → −z mirror) and cannot be scaled away.
  • Gyrotropy in the first step: breaks the complex-symmetric solver path and the reciprocity-based far field; deferred.

References

  • D. W. Berreman, "Optics in stratified and anisotropic media: 4×4-matrix formulation", J. Opt. Soc. Am. 62, 502 (1972), doi:10.1364/JOSA.62.000502.
  • P. Yeh, "Electromagnetic propagation in birefringent layered media", J. Opt. Soc. Am. 69, 742 (1979).
  • L. Li, "Fourier modal method for crossed anisotropic gratings with arbitrary permittivity and permeability tensors", J. Opt. A: Pure Appl. Opt. 5, 345–355 (2003).
  • E. Bécache, S. Fauqueux, P. Joly, "Stability of perfectly matched layers, group velocities and anisotropic waves", J. Comput. Phys. 188, 399–433 (2003).