 StaticCondensation (Index num_dofs)
 
void condense (std::span< const Index > dofs, Index num_interior, Matrix &local, Vector &load, std::vector< Index > &exterior)
 
void add_identity (SparseAssembler &assembler) const
 Adds the identity rows of all interior DoFs seen so far (call once after the cell loop).
 
Vector recover (const Vector &solution) const
 
Vector condense_load (const Vector &load) const
 
Vector recover (const Vector &solution, const Vector &load) const
 Interior recovery for a solution of the condensed system with load.
 
Vector condense_load_transposed (const Vector &functional) const
 
Vector recover_transposed (const Vector &solution, const Vector &functional) const
 
Index num_dofs () const noexcept
 
Index num_interior () const noexcept
 

Constructor & Destructor Documentation

◆ StaticCondensation()

hpfem::assembly::StaticCondensation::StaticCondensation ( Index  num_dofs)
explicit
Parameters
num_dofssize of the global system.

Member Function Documentation

◆ add_identity()

void hpfem::assembly::StaticCondensation::add_identity ( SparseAssembler &  assembler) const

Adds the identity rows of all interior DoFs seen so far (call once after the cell loop).

◆ condense()

void hpfem::assembly::StaticCondensation::condense ( std::span< const Index >  dofs,
Index  num_interior,
Matrix &  local,
Vector &  load,
std::vector< Index > &  exterior 
)

Condenses the local system of one cell in place: dofs are the cell's global DoFs in local order with the last num_interior being the interior ones; local and load shrink to the exterior block and exterior receives the exterior DoFs. The recovery data of the cell is stored (thread-safe, callable from parallel cell loops). Cells without interior DoFs pass through unchanged.

Exceptions
Errorif the interior block is singular.

◆ condense_load()

Vector hpfem::assembly::StaticCondensation::condense_load ( const Vector &  load) const

Condensed load \( \tilde f_E = f_E - K_{EB}K_{BB}^{-1}f_B \) of another full load for the same operator (interior entries zero), e.g. another incident field.

◆ condense_load_transposed()

Vector hpfem::assembly::StaticCondensation::condense_load_transposed ( const Vector &  functional) const

Condensed right-hand side of the transposed system \( K^\top z = q \) (the adjoint of the sensitivities): \( \tilde q_E = q_E - (K_{BB}^{-1}K_{BE})^\top q_B \), interior entries zero. The condensed matrix of the transposed system is the transpose of \( \tilde K_{EE} \), so its solution is a transposed solve with the factors of the condensed system.

Exceptions
InvalidArgumentif the size does not match.

◆ num_dofs()

Index hpfem::assembly::StaticCondensation::num_dofs ( ) const
inlinenoexcept

◆ num_interior()

Index hpfem::assembly::StaticCondensation::num_interior ( ) const
inlinenoexcept

◆ recover() [1/2]

Vector hpfem::assembly::StaticCondensation::recover ( const Vector &  solution) const

Fills the interior entries of a solution of the condensed system (for the loads passed to condense).

Exceptions
InvalidArgumentif the size does not match.

◆ recover() [2/2]

Vector hpfem::assembly::StaticCondensation::recover ( const Vector &  solution,
const Vector &  load 
) const

Interior recovery for a solution of the condensed system with load.

◆ recover_transposed()

Vector hpfem::assembly::StaticCondensation::recover_transposed ( const Vector &  solution,
const Vector &  functional 
) const

Interior recovery of the transposed system: \( z_B = K_{BB}^{-\top}(q_B - K_{EB}^\top z_E) \) for a solution of the condensed transposed system with right-hand side functional.